TECHNICAL DOWNLOADS
Technical datasheets and IES files for the TL track light range.
32 technical datasheets and 37 IES photometric files covering all sixteen TL01–TL05 track spotlight models — dimensions, system output and optical options on paper, plus absolute candela distributions for DIALux evo, Relux and comparable lighting design software.
READ THIS FIRST
These files are preliminary optical design models — not LM-79 measurements.
They are generated from the optical design of each model and from our internal specification sheets. They are not a laboratory measurement and not a photometric test report, and they must not be presented as one. Every file states this in its own header:
[TEST] Preliminary optical design model - not an LM-79 measurement[TESTLAB] Not applicable - in-house optical design model
Use them for design-stage modelling, layout studies and comparison between our series. Confirm final illuminance figures against measured photometry of the delivered luminaire — a measured LM-79 (or EN 13032) file set for the delivered production batch is available on request.
WHAT IS IN THE IES FILES
Data every IES file carries.
Spectral and electrical values are identical across the IES set, so those files differ only by model, power and beam angle. The datasheets above are the readable counterpart: dimensions, construction, installation and electrical data per model.
TECHNICAL DATASHEETS
One datasheet per model and colour configuration.
Each datasheet is a one-page PDF with dimensions, construction, installation, electrical data, beam-angle options and the illuminance table. Every model has two configurations, and they are not interchangeable:
Fixed colour temperature, selectable at order between 2700 K, 3000 K and 4000 K, on a standard three-circuit track. The system output figures published on this site and on the product pages are those of this configuration.
Continuously adjustable 2700 K – 6000 K on a three-circuit or DALI track. Because the same luminaire covers the whole range, system output is lower — roughly 70% of the single colour figure. Do not quote a single colour lumen value for a dual colour configuration.
| Model | Power | Dimensions | Single colour | Dual colour |
|---|---|---|---|---|
| TL01A50 | 12 W | Ø50 × 130 mm | Datasheet | Datasheet |
| TL01A60 | 20 W | Ø60 × 140 mm | Datasheet | Datasheet |
| TL01A70 | 25 W | Ø70 × 150 mm | Datasheet | Datasheet |
| TL01A80 | 30 W | Ø80 × 160 mm | Datasheet | Datasheet |
| TL01A90 | 40 W | Ø90 × 160 mm | Datasheet | Datasheet |
| TL02A65 | 15 W | Ø65 × 140 mm | Datasheet | Datasheet |
| TL02A75 | 25 W | Ø75 × 160 mm | Datasheet | Datasheet |
| TL02A85 | 35 W | Ø85 × 170 mm | Datasheet | Datasheet |
| TL03B80 | 20 W | Ø80 × 80 mm | Datasheet | Datasheet |
| TL03B90 | 30 W | Ø90 × 95 mm | Datasheet | Datasheet |
| TL03B100 | 40 W | Ø100 × 95 mm | Datasheet | Datasheet |
| TL04A80 | 15 W | Ø80 × 46 mm | Datasheet | Datasheet |
| TL04A100 | 25 W | Ø100 × 47 mm | Datasheet | Datasheet |
| TL05A65 | 15 W | Ø65 × 150 mm | Datasheet | Datasheet |
| TL05A75 | 25 W | Ø75 × 160 mm | Datasheet | Datasheet |
| TL05A85 | 35 W | Ø85 × 170 mm | Datasheet | Datasheet |
PDF, one page per datasheet, 32 files in total. Text is selectable, so every model code and parameter can be copied or searched.
DOWNLOAD BY SERIES
Sixteen models, 37 files.
Fixed-beam series (TL01 / TL02 / TL03) are supplied at both 24° and 36°. Zoom series (TL04 / TL05) are supplied at the minimum, middle and maximum zoom positions.
TL01 series · 24° / 36°
Deep front ring. Tight beam with a sharp cut-off and a very low wide-angle remainder — the low-glare option for accent and retail work.
TL02 series · 24° / 36°
Shallower front ring than TL01. Distribution and cut-off behaviour are effectively the same, so the two series are interchangeable in a calculation and differentiated by body depth.
TL03 series · 24° / 36°
Only an 8 mm front ring. Wide-angle light escapes instead of being shielded, so a high fraction of the flux leaves outside the main beam. Check the wide-angle columns before specifying — this is the bright, less-shielded family.
TL04 series · 20°–55° zoom
Thin-body zoom with a front lens. The beam is soft-edged with no concentrated shoulder, which is why the wide-angle intensity stays low even at the widest setting.
TL05 series · 15°–55° zoom
Deep-body zoom with a front lens. Above a given zoom setting part of the light escapes as a separated secondary ring, so a wide setting produces a visible double spot. This is modelled in the files and is intentional.
SCOPE AND LIMITS
What these files do not cover.
Being clear about the limits is more useful than a longer download list.
- Track lights only. Rails, connectors, adapters, housings, GU10 kits and magnetic track systems have no datasheet or photometric file here; they are not luminaires. Drawings for those are supplied per model on request.
- IES files are 3000 K only. The 2700 K and 4000 K options use the same optic, so the distribution is identical and separate IES files would add nothing. The datasheets do cover the colour configurations, including dual colour.
- IES is not measured. No LM-79 or EN 13032 test report backs the IES files, and their CCT/CRI values are design values, not measured ones.
- IES not imported-tested here. The files were validated against the LM-63-2002 structure and re-integrated against the declared system output, but we recommend you run one file through your own software before relying on a whole project.
- Datasheet values match the single colour configuration. Where a project specifies dual colour, use the dual colour datasheet's own figures.
If a project needs measured photometry on the delivered article, or files for models outside this list, tell us the model list and the software you use.
STATUS
Published 32 datasheets and 37 IES files for 16 models.
The datasheets cover both colour configurations of every model. The IES files cover the whole TL01–TL05 range at 3000 K and remain preliminary optical design models. Measured LM-79 files and EULUMDAT (.ldt) versions are the next step; both are available on request in the meantime. Nothing on this page is a certification claim — certification documents are listed separately on the certificates page.